To reset a Vokera boiler, press and hold the reset button for three to five seconds, or turn the mode selector to the reset position if your model uses a dial. Then wait a few minutes for the boiler to run its start-up checks. We’re Clever Energy Boilers: Gas Safe registered installers based in Bingley, fitting boilers across Yorkshire and the Humber, the North West and the Midlands. If your Vokera is an older model that keeps locking out, replacing it with a new boiler is the better choice for long-term efficiency and lower repair bills.
In 15 years and more than 25,000 installations, we’ve replaced plenty of tired Vokeras. This guide shows you where the reset is, how to reset safely after an A01 lockout, and the signs that a reset isn’t going to solve the problem.
How do I reset my Vokera boiler?
You reset a Vokera boiler with either a reset button or the mode selector dial on the front panel. Check the basics first so the reset has a chance of working.
- Make sure the gas is on and your meter has credit.
- Check the pressure gauge reads between 1 and 1.5 bar. Top up with the filling loop if it’s low.
- In freezing weather, thaw the condensate pipe outside with warm (not boiling) water.
- Press and hold the reset button for three to five seconds. If your model uses a dial, turn the mode selector to the reset position and hold it there for a few seconds.
- Wait a few minutes. The boiler should try to light again.
If the reset button is recessed, a pen or a small blunt tool will help you press it.
Where is the reset button on a Vokera boiler?
The reset on a Vokera boiler is on the front control panel, either as a separate button or as a reset position on the mode selector knob. The table below shows what to look for on the most common models.
| Vokera model | How to reset |
|---|---|
| Vokera Unica | Wait two minutes after the lockout, then turn the mode selector knob across the OFF/RESET position |
| Vokera Vision, Evolve and Compact | Press and hold the reset button or turn the selector to reset. Check your user guide for your exact version |
| Vokera Linea and older models | Reset button or selector on the control panel. Check your user guide |
The model name is printed on the front of the boiler or on the data badge underneath.
What does the Vokera A01 fault mean, and should I reset it?
The Vokera A01 fault means ignition failure. The boiler tried to light but couldn’t complete the ignition sequence, so it locked out for safety. You can reset an A01 fault, but only after checking why it happened.
The most common causes of a Vokera A01 are:
- No gas supply, such as an empty prepayment meter or a closed valve.
- A frozen or blocked condensate pipe.
- A damaged ignition electrode or lead.
- A faulty flame sensor or gas valve.
- A fault on the main circuit board (PCB).
The first two you can check yourself. The rest sit inside the boiler and need a Gas Safe engineer. Our guide to boiler ignition lockout explains how lockouts work across all the main brands.
Which Vokera fault codes can a reset clear?
A reset clears Vokera lockout codes like A01 once the cause has been fixed. It won’t help with a pressure fault until you’ve topped the system up, and it won’t fix a failed part. Our Vokera boiler error codes guide lists every code and what to do about each one.
Why won’t my Vokera boiler reset?
A Vokera boiler won’t reset when whatever caused the lockout is still there. If there’s no gas reaching the boiler, the pressure is too low or the condensate pipe is still frozen, the boiler will lock out again the moment it tries to light. If you’ve checked all three and it still won’t reset, the fault is internal.
If your Vokera won’t fire up at all, our guide to a boiler not firing up covers the next steps.
Why does my Vokera keep locking out?
A Vokera that keeps locking out usually has a worn ignition part, a condensate problem or a gas supply issue that keeps coming back. In winter, a condensate pipe that freezes every night is the classic cause. Out of season, it’s more often an electrode, sensor or fan wearing out.
Don’t keep resetting it. Two attempts is plenty. Repeated resets can hide a fault that’s getting worse.
Is a Vokera boiler that keeps locking out worth replacing?
A Vokera boiler that keeps locking out is usually worth replacing if it’s more than 8 years old. Older Vokeras lose efficiency over time, and spare parts for discontinued models can be slow to find. A new A-rated boiler cuts your gas use, removes the cycle of call-outs and comes with long, market-leading warranties available through us.
| Boiler age | Repeat lockouts? | Our advice |
|---|---|---|
| Under 8 years | Occasional | Safe checks, one reset, then an engineer |
| 8 to 12 years | Several a year | Get a repair quote and compare it with a new boiler |
| Over 12 years | Regular | Replacement is usually the better value |
Get a new boiler with Clever Energy
We fit new boilers across Bradford, Leeds, Huddersfield, Halifax, Wakefield and the wider Yorkshire area, plus the North West and the Midlands. Prices start from £1,999 installed, with finance options and fixed prices you can see online. Head to our boiler installation page or get your fixed price online.
Vokera boiler reset FAQs
How do I reset a Vokera boiler after a power cut?
Most Vokera boilers restart by themselves when the power comes back. If yours shows A01 or another lockout code, reset it once.
Why is a light flashing on my Vokera?
A flashing light alongside an A code on a Vokera usually means the boiler has locked out and is waiting for a reset. Check the gas and pressure, then reset once.
How many times can I reset a Vokera boiler?
Reset a Vokera no more than twice for the same fault. If it locks out again, call a Gas Safe engineer.