The F1 fault code on a Glow-worm boiler means different things depending on the age of the boiler. On older Glow-worm models, F1 is an ignition fault: the boiler couldn’t light or keep its flame, often because of a gas supply problem. On current Glow-worm boilers, F.1 points to the return temperature sensor, which has lost its connection or failed. We’re Clever Energy Boilers: Gas Safe registered installers based in Bingley, fitting boilers across Yorkshire and the Humber, the North West and the Midlands. If your Glow-worm is an older one that keeps showing F1, a new boiler is the better long-term option for efficiency and lower repair bills.
We’ve completed more than 25,000 installations in 15 years, and F1 is a Glow-worm code that confuses a lot of people, partly because many websites wrongly call it a pressure fault. This guide explains what F1 really means on your model, the checks that are safe to try, and when you need an engineer. For other codes, our Glow-worm boiler fault codes guide has the full list.
What does the F1 fault code mean on a Glow-worm boiler?
The F1 fault code on a Glow-worm boiler means one of two things, and which one depends on how old your boiler is:
| Your Glow-worm | What F1 means | Can you fix it yourself? |
|---|---|---|
| Older models | Ignition or flame failure. The boiler couldn’t light or lost its flame | Partly. Check the gas supply and condensate pipe, then reset once |
| Current models (shown as F.1) | Return temperature sensor interrupted. A loose connection or a faulty sensor | No. This needs a Gas Safe engineer |
On newer Glow-worm boilers, the old F1 ignition fault has been replaced by F28 (failed to light) and F29 (flame lost). If your boiler shows F28 or F29, our Glow-worm F28 fault guide is the one you need.
Is the Glow-worm F1 fault a low pressure fault?
No, the Glow-worm F1 fault isn’t a low pressure fault, even though plenty of websites say it is. On Glow-worm boilers, low water pressure shows as F22, or F9 on older models. Glow-worm says a flashing F22 can usually be fixed by repressurising the system. If your boiler shows F22 or F9, top it up to between 1 and 1.5 bar using the filling loop. Our guide on what boiler pressure should be explains the readings.
Why is my older Glow-worm showing an F1 fault?
An older Glow-worm shows F1 because it tried to light and couldn’t, or the flame went out. These are the usual causes:
- No gas. A prepayment meter that has run out of credit is the most common reason Glow-worm gives for ignition faults.
- A frozen or blocked condensate pipe. In cold weather, ice in the pipe backs water up into the boiler and stops it lighting.
- A worn ignition electrode or flame sensor. These wear over time and stop the boiler lighting reliably.
- A faulty gas valve or circuit board. Less common, but more likely on older boilers.
Why is my newer Glow-worm showing F.1?
A newer Glow-worm shows F.1 because the return temperature sensor isn’t sending a signal. The return sensor measures the temperature of the water coming back from your radiators. If the wire comes loose or the sensor fails, the boiler can’t monitor the system properly and shuts down. This is an internal fault, so don’t open the casing. A Gas Safe engineer will check the connection and replace the sensor if needed.
Is the Glow-worm F1 fault dangerous?
The Glow-worm F1 fault isn’t dangerous on its own. Your boiler has stopped because its safety systems spotted a problem. The only time to treat it as an emergency is if you can smell gas. If you do, open the windows, turn off the gas at the meter if you can, leave the house and call the National Gas Emergency line on 0800 111 999.
How do I fix a Glow-worm F1 fault?
You can fix an F1 fault on an older Glow-worm by checking the gas and condensate pipe, then resetting once. On a newer Glow-worm showing F.1, skip straight to an engineer.
- Check your other gas appliances work and your meter has credit.
- In freezing weather, thaw the condensate pipe with warm (not boiling) water. Our guide to defrosting your condensate pipe shows you how.
- Check the pressure is between 1 and 1.5 bar, so you can rule out an F22 too.
- Press and hold the reset button for a few seconds, then wait for the boiler to restart.
If F1 comes straight back, don’t keep resetting. Glow-worm advises using the reset procedure in your manual and not resetting repeatedly if the code returns.
When should I stop and get a Gas Safe engineer?
Stop and get a Gas Safe engineer if F1 returns after one reset, or straight away if your newer Glow-worm shows F.1. Both point to a part that needs testing or replacing. We don’t carry out boiler repairs, so for a one-off fault, a local Gas Safe engineer is the right call.
Is a recurring Glow-worm F1 fault a sign you need a new boiler?
A recurring F1 fault is often a sign you need a new boiler, especially on older Glow-worm models that still use the F1 ignition code. Those boilers are well past their best for efficiency, and parts get harder to find each year. A new A-rated boiler uses less gas, removes the cycle of breakdowns and comes with long, market-leading warranties available through us.
Get a new boiler with Clever Energy
We install new boilers across Bradford, Leeds, Huddersfield, Halifax, Wakefield and the wider Yorkshire area, plus the North West and the Midlands. Prices start from £1,999 installed, with fixed online pricing and finance options. See our boiler installation page or get your fixed price online.
Glow-worm F1 FAQs
What’s the difference between F1 and F22 on a Glow-worm?
F1 is an ignition fault on older Glow-worms and a return sensor fault on newer ones. F22 is low water pressure. Only F22 is fixed by topping up the pressure.
Why did my Glow-worm show F1 after a cold night?
On an older Glow-worm, F1 after a cold night usually means the condensate pipe froze. Thaw it with warm water and reset once.
Can I reset a Glow-worm F1 fault?
You can reset an F1 ignition fault once after checking the gas and condensate pipe. A newer boiler showing F.1 needs an engineer.
Is Glow-worm F1 the same as Vaillant F1?
Glow-worm is part of the Vaillant Group and many codes overlap, but always check the meaning for your exact model.